Crack analysis of 40Cr shifting fork |
|
|
|
Abstract Chemical composition Analysis��metallurgical analysis and other method were used to analyze the crack fault of 40Cr sliding fork. The results showed that heating temperature of workpiece was on the low side, and that transition arc angle of undercut moulding in this area in design ,which lead to blend moving of Metal Streamline ��were the major reason of causing dopplung fault.
|
Received: 13 January 2010
|
|
|
|
[1] |
WANG Ying. Fracture analysis of the[?22 mm]23MnNiCrMoA Chain[J]. Chinese Journal of Iron and Steel, 2017, 35(5): 51-55. |
[2] |
LI Ren-Jie����WANG Hao����SU Cheng��ZHANG Yuan����LI Jie5. Analysis and control of black line defect on the edge of wide and heavy plate[J]. Chinese Journal of Iron and Steel, 2017, 42(03): 71-74. |
[3] |
ZHANG Da-fu��WU An-shu��LIU Jin-yan. Cause analysis of flattening fracture of welded pipes[J]. Chinese Journal of Iron and Steel, 2016, 34(5): 41-45. |
[4] |
JIANG Bi-tao��YAN Wei-bing��LIN Teng-chang. Causes analysis of surface defect on 20 seamless steel pipe[J]. Chinese Journal of Iron and Steel, 2015, 33(5): 43-47. |
[5] |
YANG Tao��DAN Juan. Analysis of hot-rolled plate stripe shape defect[J]. Chinese Journal of Iron and Steel, 2015, 33(1): 40-44. |
[6] |
LI Ji-dong. Cause of Detection Disqualification for 30Mn2V Oil Well Pipe[J]. Chinese Journal of Iron and Steel, 2013, 31(5): 41-44. |
|
|
|
|