Abstract:Abstract:Take ABB electromagnetic stirring system core unit DSU in steel plant on the billet continuous casting machine in 8 years and the fault operation as the background, DSU fault reasons were analyzed in detail and summed up, and thoughts to inspect, operate, maintain the DSU equipment were put forward. It is emphasized that the interval length of equipment failure free operation not only depends on its quality, more on the regular use and maintenance of the equipment.
收稿日期: 2012-01-12
出版日期: 2012-07-24
引用本文:
耿庆红. 攀钢结晶器电磁搅拌系统DSU零故障运行管理[J]. 中国钢铁期刊网, 2012, 31(4): 27-31.
GENG Qing-hong. DSU Zero Fault Management of Panzhihua Mould Electromagnetic Stirring System. Chinese Journal of Iron and Steel, 2012, 31(4): 27-31.