Abstract:Recently, more and more attention has been paid to mould oscillation deflection in China, but there is no mould oscillation deflection standard . In this paper, the deflection value is analysed through arc-like vibration and the structure of vibration table; Based on experience and accumulated data, the oscillation deflection standard of mould is obtained. So as to judge whether the oscillation deflection of the mould is qualified.