Abstract: The influencing factors of ferrous charges consumption on a 100t converter were investigated in Angang first steelmaking and rolling plant. The ferrous charges consumption was reduced to 1042.52kg for each ton steel in 2009. The technology and management measures were proposed in raw and auxiliary materials, smelting process, slagging regime, endpoint control,secondary refining and continuous casting, which reduced costs and increased effectively social and economical benefits.
石中雪,杨俊锋,徐新琰,倪冰. 降低100 t转炉钢铁料消耗的工艺研究[J]. 钢铁, 2011, 46(5): 28-32.
SHI Zhongxue1,YANG Junfeng1,XU Xinyan1,NI Bing2. Technological Study of Reducing Ferrous Charges Consumption on a 100t Converter. Iron and Steel, 2011, 46(5): 28-32.