Experimental Research on Desulphurization of Sintering Flue Gas With Coking Wastewater in Spray Tower

CHENG Zewei;ZHANG Guangbin;CANG Daqiang;ZONG Yanbing

Iron and Steel ›› 2008, Vol. 43 ›› Issue (10) : 82-0.

Welcome to visit Iron and Steel, August 1, 2025
Iron and Steel ›› 2008, Vol. 43 ›› Issue (10) : 82-0.
环保与能源

Experimental Research on Desulphurization of Sintering Flue Gas With Coking Wastewater in Spray Tower

Author information +
History +

Abstract

A spray tower was built, and experiment was carried out on desulfurization of sintering flue gas with coking wastewater. Factors as inlet SO2 concentration of sintering flue gas, pH values of coking wastewater and temperature were studied to find the impacts on desulfurization. The outlet SO2 concentration was 118 mg/m3, and desulphurization efficiency was 97% when the inlet SO2 concentration was 4000 mg/m3, temperature was 2 ℃, and pH values of coking wastewater was 9.0. The desulphurization rate and removed sulphur increased with the inlet SO2 concentration.Desulphurization efficiency can be improved with decrease of pH value of coking wastewater and increase of temperature.

Key words

sintering flue gas / coking wastewater / desulphurization

Cite this article

Download Citations
CHENG Zewei, ZHANG Guangbin, CANG Daqiang, et al. Experimental Research on Desulphurization of Sintering Flue Gas With Coking Wastewater in Spray Tower[J]. Iron and Steel, 2008, 43(10): 82-0