投审稿入口

半无限长动态压力探针引压管结构参数对其动态特性影响的实验研究

Experimental study on the influence of structural parameters of semi-infinite dynamic pressure probe tubing on its dynamic characteristics

  • 摘要: 为提升燃气轮机燃烧室动态压力测量精度,文章研究引压管结构参数对其动态响应特性的影响,重点探明大振幅激励下的非线性动力学行为。基于管道声波传播理论,实验采用调制式动态压力发生器,测试多种长度(20~200 mm)与直径(2~6 mm)引压管的响应特性。结果表明:引压管长度主导相位滞后,相位差与管长和频率的乘积成正比;安装座反射是引起系统幅频特性共振峰的关键因素;直径影响由阻抗匹配状态主导——当主管道直径与前后固定管段一致时,阻抗连续,系统表现为传输线特性;当直径失配时,系统变为谐振器,小管径(高阻抗)激发高频共振,大管径(低阻抗)激发低频共振,大振幅激励下非线性效应进一步放大共振峰,出现增益大于1的异常放大现象,突破了经典线性声学理论预测。研究揭示了大振幅条件下引压管动态响应中线性耗散与非线性共振竞争的频域机理,对高精度动态压力测量系统的设计与信号修正具有重要指导意义。

     

    Abstract: To improve the accuracy of dynamic pressure measurement in gas turbine combustors, this study investigates the influence of structural parameters of pressure tubing on its dynamic response characteristics, with emphasis on nonlinear behaviors under large-amplitude excitation. Based on the theory of acoustic wave propagation in pipelines, experiments were conducted using a modulated dynamic pressure generator to test pressure tubes with various lengths(20-200 mm) and diameters(2-6 mm). Results show that tube length dominates the phase lag, with phase difference proportional to the product of length and frequency. Reflection from the mounting seat is identified as the key factor causing resonance peaks in amplitude-frequency characteristics. The effect of diameter is governed by impedance matching: when the main tube diameter matches the fixed upstream and downstream sections, the system behaves as a transmission line with continuous impedance; when mismatched, the system becomes a resonator—small diameter(high impedance) excites high-frequency resonance, while large diameter(low impedance) excites low-frequency resonance. Under large-amplitude excitation, nonlinear effects further amplify the resonance peak of the small-diameter tube, resulting in gain exceeding unity—an abnormal amplification that deviates from classical linear acoustic theory. This study reveals the frequency-domain competition between linear dissipation and nonlinear resonance in the dynamic response of pressure tubes under large-amplitude conditions, providing guidance for the design and signal correction of high-precision dynamic pressure measurement systems.

     

/

返回文章
返回