首钢股份1号高炉炉役后期铜冷却壁维护措施
Maintenance measures of copper cooling staves in the late campaign of Shougang No.1 BF
-
摘要: 首钢股份1号高炉炉役后期出现铜冷却壁集中破损,通过采取一系列维护措施,铜冷却壁损坏状况得到有效控制。认为:(1)精准调控边沿气流是延长铜冷却壁寿命的核心;(2)炉料调控体系基于“四稳定”原则,为煤气流的控制提供物质基础;(3)应用多管并联穿管修复技术是炉役后期维护铜冷却壁的有效手段;(4)棋盘式布局的铜冷却柱强化体系,通过横向热扩散层与纵向铜柱协同作用,能有效缓解局部热应力集中效应。一旦出现铜冷却壁损坏,建议采取分级治理策略进行应对,实施维护的优先顺序为,操作调控边沿气流→应用多管修复技术→建立铜冷却柱强化体系。Abstract: No.1 blast furnace of Shougang experiences severe copper cooling staves damage in its late campaign stage,and this problem gets controlled by taking a set of maintenance measures.It is believed that:(1) accurate control of the edge gas flow is the core factor of prolonging the service life of copper cooling staves;(2) the burden distribution control system which is established based on the principle of " four stabilities" provides the material foundation for controlling the gas flow;(3) insertion of multiple parallel tubes into the damaged cooling pipe is an effective copper cooling staves repair technology in the later campaign stage;(4) the reinforced structure of columnar copper coolers that are arranged like a chessboard can effectively relieve local heat stress concentration through the co-action of the transverse heat diffusion pipes and the longitudinal copper cooling pipes.Once the copper cooling staves are found damaged,it is suggested to implement stepwise handling strategy according to priority order of edge gas flow adjustment→application of multi-tube insertion repair technology→setup of the copper cooling pipe reinforcement system.