唐钢新区2号高炉冷却壁损坏原因及治理措施
Causes of cooling stave damage and maintenance practices of No.2 BF in Tangsteel New Area
-
摘要: 唐钢新区2号高炉生产期间,冷却壁水管破损影响了炉况顺行。认为:(1)在焦炭质量较差且冶炼强度较高时,边沿气流不稳定,会加快铸铁冷却壁的损坏速度;(2)冶炼强度大,造成炉料对冷却壁的磨损加剧;(3)当炉料结构发生变化时,应及时改变高炉操作制度,确保将炉体热负荷、冷却壁壁体温度及温度梯度分布控制在合理范围,以形成合理的操作炉型,延长冷却壁的使用寿命;(4)硬质压入料造衬有效缓解了高炉冷却壁水管破损对炉况的影响。Abstract: The cooling stave water pipes of No.2 blast furnace in Tangsteel New Area are damaged during operation,which affects smooth running of the furnace.It is believed after analysis:(1) unstable edge gas flow gears up the damage of cast iron cooling staves under the conditions of poor coke quality and high smelting intensity;(2) high smelting intensity enhances the cooling stave wearing by the burden;(3) when burden mix changes,the blast furnace operating system should be adjusted duly to ensure that furnace heat load,cooling stave body temperature,and temperature gradient can be controlled within an appropriate ranges to enable the formation of a proper furnace operating profile and extend the service life of the cooling staves;(4) application of hard injection mix for furnace relining alleviates the impact of cooling stave water pipe damage on furnace conditions.