投审稿入口

基于空气耦合超声技术的多层泡沫粘接复合材料检测工艺参数探讨

Discussion on testing process parameters of multilayer foam bonding composites based on air-coupled ultrasonic technology

  • 摘要: 多层泡沫粘接复合材料内部存在大量的多孔/蜂窝孔结构,在采用常规超声技术开展无损检测时难以实现超声波的有效耦合与入射,使得其内部缺陷的超声检测成为行业共性难题。本文采用空气作为超声耦合介质开展多层泡沫粘接复合材料无损检测,并结合该类型复合材料的实测数据确定了关键工艺参数。选取空气耦合超声技术(ACUT)的关键检测参数如探头间距、脉冲串数、平均次数、中心频率、前置放大比例、滤波频率等作为研究变量,讨论了各参数对缺陷回波信号幅值的影响规律,确定了适配多层泡沫粘接复合材料超声检测的优化参数:探头间距为250 mm、脉冲串数为5、平均次数为1、中心频率为140 kHz、前置放大比例为20%、滤波范围为80~200 Hz。通过在功能性材料界面处制备包含不同深度和尺寸的多层泡沫粘接复合材料缺陷试样,采用优化参数后的空气耦合超声技术进行检测。结果表明,对于预制直径为20、30和50 mm的圆形缺陷,检测结果的最大相对误差分别为7.50%、5.00%和4.00%。由此证实,空气耦合超声技术可实现对该类复合材料内部不同深度位置处界面脱粘缺陷的定量检测。

     

    Abstract: Multilayer foam bonding composites contains a large number of porous/honeycomb structures, making it difficult to achieve effective ultrasonic coupling and incidence when conducting non-destructive testing with conventional ultrasonic techniques. This results in ultrasonic detection of internal defects becoming a common industry challenge. This paper employs air as the ultrasonic coupling medium for non-destructive testing of multilayer foam bonding composites, and determines key process parameters based on measured data from this type of composite. The key detection parameters of air-coupled ultrasonic technique (ACUT), such as probe spacing, pulse string number, average count, center frequency, preamplification ratio, and filtering frequency, are selected as the research variables. The influence laws of each parameter on the amplitude of defect echo signals are discussed, and the optimized parameters suitable for ultrasonic testing of multi-layer foam bonding composites are determined: the probe spacing is 250 mm, the pulse string number is 5, the average count is 1, the center frequency is 140 kHz, the preamplification ratio is 20%, and the filtering frequency is 80-200 Hz. By preparing multilayer foam bonding composite defect samples with different depths and sizes at the interface of functional materials, the air-coupled ultrasonic technology with optimized parameters is used for detection. The results show that the maximum relative errors of detection results are 7.50%, 5.00% and 4.00% for prefabricated circular defects with diameters of 20, 30 and 50 mm, respectively. This confirms that the air-coupled ultrasonic technique can achieve quantitative detection of interfacial debonding defects at different depths inside this type of composite.

     

/

返回文章
返回