PreTreatment of TinPlating Wastewater From Cold Strip Mill With H2O2Ferric/Carbon
LIN Yongzeng1,2,LIU Meiying1,LIU Xianghua1,WANG Guodong1
1. State Key Lab of Rolling and Automation, Northeastern University, Shenyang 110004, Liaoning,China;2. Baosteel Branch, Baosteel Co., Ltd., Shanghai 200431, China
Abstract:There is a plenty of organic matters in wastewater from tin electroplating process of cold rolling mill.The concentration of COD is high and pH is between 1.12.0.So it is difficult to treat directly by biochemical process. H2O2ferric/activated carbonpH calibrationcoagulation process was used to pretreat such wastewater. The results showed that the effect is the best when void speed is 3 h-1, H2O2/COD is 1.5, pH is about 8 and the dosage of PAM is 5 mg/m3.The chemical oxygen demands (COD) can be reduced and the Sn2+ removed by precipitation as Sn4+ after oxidation.The pretreatment provides necessary conditions for the further biological process.
林永增;刘梅英;刘相华;王国栋. H2O2铁炭法预处理冷轧带钢厂镀锡废水[J]. 钢铁, 2007, 42(5): 79-0.